Description
Tester |
High voltage detector |
Mainframe (current clamp) |
Range |
0.0mA~1200A(50/60Hz Auto) |
0.0mA~20A |
Resolution |
0.1mA |
0.1mA |
Jaw size |
φ50mm |
φ7.5mm |
Accuracy |
±2%±5dgt |
±0.5%±5dgt |
Sampling Rate |
2 times/second |
|
Function |
High-low voltage current transformer primary and secondary loop current, transformation ratio, polarity, phase, and on-line test; current and voltage ratio on both sides of transformer; on-line test; load current test |
|
Transmission type |
Wireless transmission, linear transmission distance 30m |
|
Change gear |
Fully automatic shift |
|
Power |
DC6V 7# alkaline battery(1.5V AAA×4) |
DC7.5V 5# alkaline battery(1.5V LR6×5) |
Test method |
Clamp CT |
|
Dimensions |
W/T/H 87*37*262mm |
Host:W/T/H 100*35*204mm |
|
|
Current clamp:W/T/H 42*20*137mm |
Display mode |
LCD:128dots×64dots Blue screen backlight for dim places |
|
LCD Size |
62mm×44mm |
|
Change ratio |
Three kinds of transformation ratio display: (The primary and secondary circuit actually measured the current transformation ratio; the conversion ratio of the secondary circuit 5A; 10kV-YY transformer conversion ratio of 10kV/380V), the maximum ratio of 1:1 million |
|
Line voltage |
Line test with insulation sheath below 60kV or bare wire current test below 35kV (with insulation rod operation) |
|
Lead length |
Current clamp lead 2 meters |
|
Weight |
Total instrument weight:7Kg(Insulated rod and instrument package) |
|
|
High pressure detector:370g(Including battery) |
|
|
Host:409g(Including battery) |
|
|
Current clamp:180g |
|
Data interface |
USB transmission |
|
Overflow display |
Over-range overflow function: “OL A” symbol display |
|
Data storage |
500 groups, press MENU to keep data, HOLD symbol display, press MENU again to cancel |
|
Data review |
Long press the MENU button to enter the data reference mode, MR symbol display, press MENU again to exit |
|
Data is full |
Data full function: “FULL” symbol display |
|
Switch display mode |
Long press the POWER button to switch between the test display mode and the conversion ratio display mode |
|
No signal indication |
When the host does not receive the transmit signal, it prompts “no signal” |
|
Automatic shut-down |
About 15 minutes after power on, the meter will automatically shut down |
|
Battery voltage |
When the battery voltage drops to 3.5V, the low-power indicator lights to remind you to replace the battery |
When the battery voltage drops to 5.2V, the battery voltage is low symbol to remind to replace the battery |
Insulation rod |
Five section insulation rod (5 meters) |
|
Insulation strength |
AC 60kV/rms |
|
Line test |
Insulation sheath wire test below 60kV line voltage, bare wire test below 60kV (with insulation rod operation) |
|
Working temperature |
-10℃~40℃ |
|
Storage temperature |
-10℃~60℃ |
|
Relative humidity |
0℃~31℃≦75%,31℃~40℃≦50% |
|
Suitable for safety regulations |
IEC1010-1、IEC1010-2-032、Pollution degree 2、CAT Ⅲ(600V) IEC61326(EMC standard) |