Refine search Refine search

In stock
10 days
DOMAE-16A
Ampere: 16A, Poles Description: 1 Pole, Brand: Schneider Electric
Main Range Domae Device application Protection Product or component type Residual current breaker with overcurrent protection (RCBO) Poles description 1P + N Neutral position Left Earth-leakage protection class Type AC suitability for isolation Yes Complementary [In] rated current 6 A Network type AC Network frequency 50 Hz [Ue] rated operational voltage 230 V AC 50 Hz conforming to IEC 61009-1 Trip unit technology Thermal-magnetic Curve code C Magnetic tripping limit 5...10 x In...
Poles Description:
1 Pole
Poles Description: 1 Pole
In stock
7 days
EZ9F46116
Ampere: 16A, Brand: Schneider Electric, Ampere(C): 16A
Range Easy9 Device application Distribution product or component type Miniature circuit-breaker Device short name Easy9 MCB Poles 1P Number of protected poles 1 [In] rated current 16 A Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 6000 A Icn at 230 V AC 50/60 Hz conforming to IEC 60898-1 Suitability for isolation Yes conforming to IEC 60898-1
Ampere(C): 16A
In stock
7 days
EZ9F46110
Ampere: 10A, Brand: Schneider Electric, Ampere(C): 10A
Range Easy9 Device application Distribution product or component type Miniature circuit-breaker Device short name Easy9 MCB Poles 1P Number of protected poles 1 [In] rated current 10 A Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 4500 A Icn at 230 V AC 50/60 Hz conforming to IEC 60898-1 4500 A Icn at 400 V AC 50/60 Hz conforming to IEC 60898-1 Suitability for isolation Yes conforming to IEC...
Ampere(C): 10A
In stock
7 days
17045
Ampere: 10A, Brand: Schneider Electric, Ampere(C): 10A
Main Range Domae product or component type Miniature circuit-breaker Device short name Domae MCB Device application Distribution Poles description 1P Number of protected poles 1 [In] rated current 10 A Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity Icn 6000 A Complementary Network frequency 50/60 Hz [Ue] rated...
Ampere(C): 10A
In stock
7 days
EZ9F46132
Ampere: 32A, Brand: Schneider Electric, Ampere(C): 32A
Range Easy9 Device application Distribution product or component type Miniature circuit-breaker Device short name Easy9 MCB Poles 1P Number of protected poles 1 [In] rated current 32 A Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 6000 A Icn at 230 V AC 50/60 Hz conforming to IEC 60898-1 10000 A Icn at 127 V AC 50/60 Hz conforming to IEC 60898-1 Suitability for isolation Yes conforming to...
Ampere(C): 32A
In stock
7 days
EZ9F46125
Ampere: 25A, Brand: Schneider Electric, Ampere(C): 25A
Range Easy9 Device application Distribution product or component type Miniature circuit-breaker Device short name Easy9 MCB Poles 1P Number of protected poles 1 [In] rated current 25 A Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 4500 A Icn at 230 V AC 50/60 Hz conforming to IEC 60898-1 4500 A Icn at 400 V AC 50/60 Hz conforming to IEC 60898-1 Suitability for isolation Yes conforming to IEC...
Ampere(C): 25A
In stock
7 days
17044
Ampere: 6A, Brand: Schneider Electric, Ampere(C): 6A
Main Range Domae product or component type Miniature circuit-breaker Device short name Domae MCB Device application Distribution Poles description 1P Number of protected poles 1 [In] rated current 6 A Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity Icn 6000 A Complementary Network frequency 50/60 Hz [Ue] rated...
Ampere(C): 6A
In stock
7 days
17047
Ampere: 20A, Brand: Schneider Electric, Ampere(C): 20A
Main Range Domae product or component type Miniature circuit-breaker Device short name Domae MCB Device application Distribution Poles description 1P Number of protected poles 1 [In] rated current 20 A Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity Icn 6000 A Complementary Network frequency 50/60 Hz [Ue] rated...
Ampere(C): 20A
In stock
7 days
A9F44104
Ampere: 4A, Brand: Schneider Electric, Ampere(C): 4A
Main Range Acti9 Product name Disbo iC60 product or component type Miniature circuit-breaker Device short name IC60N Poles description 1P Number of protected poles 1 [In] rated current 4 A Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 50 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC...
Ampere(C): 4A
In stock
7 days
A9F44106
Ampere: 6A, Brand: Schneider Electric, Ampere(C): 6A
Main Range Acti9 Product name Disbo iC60 product or component type Miniature circuit-breaker Device short name IC60N Poles description 1P Number of protected poles 1 [In] rated current 6 A Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 10 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 6000 A Icn at 240...
Ampere(C): 6A
In stock
7 days
17049
Ampere: 32A, Brand: Schneider Electric, Ampere(C): 32A
Main Range Domae product or component type Miniature circuit-breaker Device short name Domae MCB Device application Distribution Poles description 1P Number of protected poles 1 [In] rated current 32 A Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity Icn 6000 A Complementary Network frequency 50/60 Hz [Ue] rated...
Ampere(C): 32A
In stock
7 days
A9F44132
Ampere: 32A, Brand: Schneider Electric, Ampere(C): 32A
Main Range Acti9 Product name Disbo iC60 product or component type Miniature circuit-breaker Device short name IC60N Poles description 1P Number of protected poles 1 [In] rated current 32 A Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 10 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 6000 A Icn at...
Ampere(C): 32A
In stock
7 days
A9F44150
Ampere: 50A, Brand: Schneider Electric, Ampere(C): 50A
Main Range Acti9 Product name Disbo iC60 product or component type Miniature circuit-breaker Device short name IC60N Poles description 1P Number of protected poles 1 [In] rated current 50 A Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 10 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 6000 A Icn at...
Ampere(C): 50A
In stock
7 days
A9N61501
Ampere: 1A, Brand: Schneider Electric, Ampere(C): 1A
  Range Acti9 Product name Acti9 C60H-DC product or component type Miniature circuit-breaker Device short name C60H-DC Device application Distribution poles description 1P Number of protected poles 1 [In] rated current 1 A at 25 °C Network type DC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 10 kA Icu at 220 V DC conforming to EN 60947-2 10 kA Icu at 220 V DC...
Ampere(C): 1A
In stock
7 days
EZ9F46140
Ampere: 40A, Brand: Schneider Electric, Ampere(C): 40A
Range Easy9 Device application Distribution product or component type Miniature circuit-breaker Device short name Easy9 MCB Poles 1P Number of protected poles 1 [In] rated current 40 A Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 4500 A Icn at 230 V AC 50/60 Hz conforming to IEC 60898-1 4500 A Icn at 400 V AC 50/60 Hz conforming to IEC 60898-1 Suitability for isolation Yes conforming to IEC...
Ampere(C): 40A
In stock
7 days
A9F44102
Ampere: 2A, Brand: Schneider Electric, Ampere(C): 2A
Main Range Acti9 Product name Disbo iC60 product or component type Miniature circuit-breaker Device short name IC60N Poles description 1P Number of protected poles 1 [In] rated current 2 A Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 50 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC...
Ampere(C): 2A
In stock
7 days
A9F44110
Ampere: 10A, Brand: Schneider Electric, Ampere(C): 10A
Main Range Acti9 Product name Disbo iC60 product or component type Miniature circuit-breaker Device short name IC60N Poles description 1P Number of protected poles 1 [In] rated current 10 A Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 10 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 6000 A Icn at...
Ampere(C): 10A
In stock
7 days
17050
Ampere: 40A, Brand: Schneider Electric, Ampere(C): 40A
Main Range Domae product or component type Miniature circuit-breaker Device short name Domae MCB Device application Distribution Poles description 1P Number of protected poles 1 [In] rated current 40 A Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity Icn 6000 A Complementary Network frequency 50/60 Hz [Ue] rated...
Ampere(C): 40A
In stock
7 days
A9F44101
Ampere: 1A, Brand: Schneider Electric, Ampere(C): 1A
Main Range Acti9 Product name Disbo iC60 product or component type Miniature circuit-breaker Device short name IC60N Poles description 1P Number of protected poles 1 [In] rated current 1 A Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 50 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC...
Ampere(C): 1A
In stock
7 days
A9F44163
Ampere: 63A, Brand: Schneider Electric, Ampere(C): 63A
Main Range Acti9 Product name Disbo iC60 product or component type Miniature circuit-breaker Device short name IC60N Poles description 1P Number of protected poles 1 [In] rated current 63 A Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 10 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 6000 A Icn at...
Ampere(C): 63A
In stock
7 days
A9F44120
Ampere: 20A, Brand: Schneider Electric, Ampere(C): 20A
Main Range Acti9 Product name Disbo iC60 product or component type Miniature circuit-breaker Device short name IC60N Poles description 1P Number of protected poles 1 [In] rated current 20 A Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 10 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 6000 A Icn at...
Ampere(C): 20A
In stock
7 days
A9F54106
Ampere: 6A, Brand: Schneider Electric, Ampere(C): 6A
Main Range Acti9 Product name Disbo iC60 product or component type Miniature circuit-breaker Device short name iC60H poles description 1P Number of protected poles 1 [In] rated current 6 A Network type AC/DC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 20 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 15 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 10000 A Icn at...
Ampere(C): 6A
In stock
7 days
A9A26929
Main range of product Acti9 product or component type Double OC or fault contact Device short name iOF/SD+OF Signal contacts composition 2 C/O [In] rated current DC-12 1 A at 130 V, DC DC-12 1.5 A at 60 V, DC DC-12 2 A at 48 V, DC DC-12 6 A at 24 V, DC AC-12 3 A at 415 V, AC 50/60 Hz AC-12 6 A at 240 V, AC 50/60 Hz 9 mm pitches 1
In stock
7 days
17048
Ampere: 25A, Brand: Schneider Electric, Ampere(C): 25A
Main Range Domae product or component type Miniature circuit-breaker Device short name Domae MCB Device application Distribution Poles description 1P Number of protected poles 1 [In] rated current 25 A Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity Icn 6000 A Complementary Network frequency 50/60 Hz [Ue] rated...
Ampere(C): 25A
In stock
7 days
A9F44116
Ampere: 16A, Brand: Schneider Electric, Ampere(C): 16A
Main Range Acti9 Product name Disbo iC60 product or component type Miniature circuit-breaker Device short name IC60N Poles description 1P Number of protected poles 1 [In] rated current 16 A Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 10 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 6000 A Icn at...
Ampere(C): 16A
In stock
7 days
A9F44125
Ampere: 25A, Brand: Schneider Electric, Ampere(C): 25A
Main Range Acti9 Product name Disbo iC60 product or component type Miniature circuit-breaker Device short name IC60N Poles description 1P Number of protected poles 1 [In] rated current 25 A Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 10 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 6000 A Icn at...
Ampere(C): 25A
In stock
7 days
A9N61515
Ampere: 32A, Brand: Schneider Electric, Ampere(C): 32A
Main Range Acti9 Product name Acti9 C60H-DC product or component type Miniature circuit-breaker Device short name C60H-DC Device application Distribution poles description 1P Number of protected poles 1 [In] rated current 32 A at 25 °C Network type DC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 10 kA Icu at 220 V DC conforming to EN 60947-2 10 kA Icu...
Ampere(C): 32A
In stock
7 days
EZ9F46106
Ampere: 6A, Brand: Schneider Electric, Ampere(C): 6A
Range Easy9 Device application Distribution product or component type Miniature circuit-breaker Device short name Easy9 MCB Poles 1P Number of protected poles 1 [In] rated current 6 A Network type AC Trip unit technology Thermal-magnetic Curve code B Breaking capacity 6000 A Icn at 230 V AC 50/60 Hz phase to neutral conforming to BS EN 60898-1 6000 A Icn at 400 V AC 50/60 Hz phase to phase conforming to BS EN 60898-1 Suitability for...
Ampere(C): 6A
In stock
7 days
A9F54150
Ampere: 50A, Brand: Schneider Electric, Ampere(C): 50A
Main Range Acti9 Product name Disbo iC60 product or component type Miniature circuit-breaker Device short name iC60H poles description 1P Number of protected poles 1 [In] rated current 50 A Network type AC/DC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 20 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 15 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 10000 A Icn...
Ampere(C): 50A
In stock
7 days
A9F54110
Ampere: 10A, Brand: Schneider Electric, Ampere(C): 10A
Main Range Acti9 Product name Disbo iC60 product or component type Miniature circuit-breaker Device short name iC60H Poles description 1P Number of protected poles 1 [In] rated current 10 A Network type AC/DC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 20 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 15 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 10000 A Icn...
Ampere(C): 10A
In stock
7 days
A9N61518
Ampere: 50A, Brand: Schneider Electric, Ampere(C): 50A
Main Range Acti9 Product name Acti9 C60H-DC product or component type Miniature circuit-breaker Device short name C60H-DC Device application Distribution poles description 1P Number of protected poles 1 [In] rated current 50 A at 25 °C Network type DC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 10 kA Icu at 220 V DC conforming to EN 60947-2 10 kA Icu...
Ampere(C): 50A
In stock
7 days
17046
Ampere: 16A, Brand: Schneider Electric, Ampere(C): 16A
Main Range Domae product or component type Miniature circuit-breaker Device short name Domae MCB Device application Distribution Poles description 1P Number of protected poles 1 [In] rated current 16 A Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity Icn 6000 A Complementary Network frequency 50/60 Hz [Ue] rated...
Ampere(C): 16A
In stock
7 days
A9N18357
Ampere: 80A, Brand: Schneider Electric, Ampere(C): 80A
Main Range of product C120 Range Acti9 Product name C120 product or component type Miniature circuit-breaker Device short name C120N Device application Distribution poles description 1P Number of protected poles 1 [In] rated current 80 A at 30 °C Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 3 kA Icu at 380...415 V...
Ampere(C): 80A
In stock
7 days
A9N18358
Ampere: 100A, Brand: Schneider Electric, Ampere(C): 100A
Main Range of product C120 Range Acti9 Product name C120 product or component type Miniature circuit-breaker Device short name C120N Device application Distribution Poles description 1P Number of protected poles 1 [In] rated current 100 A at 30 °C Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 3 kA Icu at 380...415 V...
Ampere(C): 100A
In stock
7 days
A9A26960
range of product Acti9 product or component type Undervoltage release Device short name iMN [Uc] control circuit voltage 220...240 V AC 50/60 Hz Control type Standard 9 mm pitches 2
In stock
7 days
A9F44140
Ampere: 40A, Brand: Schneider Electric, Ampere(C): 40A
Main Range Acti9 Product name Disbo iC60 product or component type Miniature circuit-breaker Device short name IC60N Poles description 1P Number of protected poles 1 [In] rated current 40 A Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 10 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 6000 A Icn at...
Ampere(C): 40A
In stock
7 days
A9F54132
Ampere: 32A, Brand: Schneider Electric, Ampere(C): 32A
Main Range Acti9 Product name Disbo iC60 product or component type Miniature circuit-breaker Device short name iC60H Poles description 1P Number of protected poles 1 [In] rated current 32 A Network type AC/DC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 20 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 15 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 10000 A Icn...
Ampere(C): 32A
In stock
7 days
A9F54120
Ampere: 20A, Brand: Schneider Electric, Ampere(C): 20A
Main Range Acti9 Product name Disbo iC60 product or component type Miniature circuit-breaker Device short name iC60H poles description 1P Number of protected poles 1 [In] rated current 20 A Network type AC/DC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 20 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 15 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 10000 A Icn...
Ampere(C): 20A
In stock
7 days
A9A26476
Main range of product Acti9 product or component type Shunt trip release Device short name iMX [Uc] control circuit voltage 100...415 V AC 50/60 Hz 110...130 V DC 9 mm pitches 2
In stock
7 days
A9N61502
Ampere: 2A, Brand: Schneider Electric, Ampere(C): 2A
Main Range Acti9 Product name Acti9 C60H-DC product or component type Miniature circuit-breaker Device short name C60H-DC Device application Distribution poles description 1P Number of protected poles 1 [In] rated current 2 A at 25 °C Network type DC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 10 kA Icu at 220 V DC conforming to EN 60947-2 10 kA Icu at...
Ampere(C): 2A
In stock
7 days
A9N61504
Ampere: 4A, Brand: Schneider Electric, Ampere(C): 4A
Main Range Acti9 Product name Acti9 C60H-DC product or component type Miniature circuit-breaker Device short name C60H-DC Device application Distribution poles description 1P Number of protected poles 1 [In] rated current 4 A at 25 °C Network type DC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 10 kA Icu at 220 V DC conforming to EN 60947-2 10 kA Icu at...
Ampere(C): 4A
In stock
7 days
A9N61512
Ampere: 20A, Brand: Schneider Electric, Ampere(C): 20A
  Range Acti9 Product name Acti9 C60H-DC product or component type Miniature circuit-breaker Device short name C60H-DC Device application Distribution Poles description 1P Number of protected poles 1 [In] rated current 20 A at 25 °C Network type DC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 10 kA Icu at 220 V DC conforming to EN 60947-2 10 kA Icu at 220 V...
Ampere(C): 20A
In stock
7 days
EZ9F46120
Ampere: 20A, Brand: Schneider Electric, Ampere(C): 20A
Range Easy9 Device application Distribution product or component type Miniature circuit-breaker Device short name Easy9 MCB Poles 1P Number of protected poles 1 [In] rated current 20 A Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 6000 A Icn at 230 V AC 50/60 Hz phase to neutral conforming to BS EN 60898-1 6000 A Icn at 400 V AC 50/60 Hz phase to phase conforming to BS EN 60898-1 Suitability for...
Ampere(C): 20A
In stock
7 days
A9F54163
Ampere: 63A, Brand: Schneider Electric, Ampere(C): 63A
Main Range Acti9 Product name Disbo iC60 product or component type Miniature circuit-breaker Device short name iC60H poles description 1P Number of protected poles 1 [In] rated current 63 A Network type AC/DC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 20 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 15 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 10000 A Icn...
Ampere(C): 63A
In stock
7 days
A9N18359
Ampere: 125A, Brand: Schneider Electric, Ampere(C): 125A
Main Range of product C120 Range Acti9 Product name C120 product or component type Miniature circuit-breaker Device short name C120N Device application Distribution poles description 1P Number of protected poles 1 [In] rated current 125 A at 30 °C Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 3 kA Icu at 380...415 V...
Ampere(C): 125A
In stock
7 days
A9A26924
Main range of product Acti9 product or component type OC contact Device short name iOF Signal contacts composition 1 C/O [In] rated current AC-12 6 A at 240 V, AC 50/60 Hz AC-12 3 A at 415 V, AC 50/60 Hz DC-12 2 A at 48 V, DC DC-12 1.5 A at 60 V, DC DC-12 1 A at 130 V, DC DC-12 6 A at 24 V, DC 9 mm pitches 1
In stock
7 days
A9F54140
Ampere: 40A, Brand: Schneider Electric, Ampere(C): 40A
Main Range Acti9 Product name Disbo iC60 product or component type Miniature circuit-breaker Device short name iC60H poles description 1P Number of protected poles 1 [In] rated current 40 A Network type AC/DC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 20 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 15 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 10000 A Icn...
Ampere(C): 40A
In stock
7 days
A9A26927
Main range of product Acti9 product or component type Fault contact Device short name iSD Signal contacts composition 1 C/O [In] rated current DC-12 1 A at 130 V, DC DC-12 1.5 A at 60 V, DC DC-12 2 A at 48 V, DC DC-12 6 A at 24 V, DC AC-12 3 A at 415 V, AC 50/60 Hz AC-12 6 A at 240 V, AC 50/60 Hz 9 mm pitches 1
In stock
7 days
A9N61506
Ampere: 6A, Brand: Schneider Electric, Ampere(C): 6A
Main Range Acti9 Product name Acti9 C60H-DC product or component type Miniature circuit-breaker Device short name C60H-DC Device application Distribution poles description 1P Number of protected poles 1 [In] rated current 6 A at 25 °C Network type DC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 10 kA Icu at 220 V DC conforming to EN 60947-2 10 kA Icu at...
Ampere(C): 6A
In stock
7 days
A9N61513
Ampere: 25A, Brand: Schneider Electric, Ampere(C): 25A
Main Range Acti9 Product name Acti9 C60H-DC product or component type Miniature circuit-breaker Device short name C60H-DC Device application Distribution Poles description 1P Number of protected poles 1 [In] rated current 25 A at 25 °C Network type DC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 10 kA Icu at 220 V DC conforming to EN 60947-2 10 kA Icu...
Ampere(C): 25A