Refine search Refine search

In stock
7 days
17058
Ampere: 6A, Brand: Schneider Electric, Ampere(C): 6A
Main Range Domae product or component type Miniature circuit-breaker Device short name Domae MCB Device application Distribution Poles description 2P Number of protected poles 2 Neutral position Left [In] rated current 6 A Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity Icn 6000 A Complementary Network frequency...
Ampere(C): 6A
In stock
7 days
A9F44101
Ampere: 1A, Brand: Schneider Electric, Ampere(C): 1A
Main Range Acti9 Product name Disbo iC60 product or component type Miniature circuit-breaker Device short name IC60N Poles description 1P Number of protected poles 1 [In] rated current 1 A Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 50 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC...
Ampere(C): 1A
In stock
7 days
A9F44106
Ampere: 6A, Brand: Schneider Electric, Ampere(C): 6A
Main Range Acti9 Product name Disbo iC60 product or component type Miniature circuit-breaker Device short name IC60N Poles description 1P Number of protected poles 1 [In] rated current 6 A Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 10 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 6000 A Icn at 240...
Ampere(C): 6A
In stock
7 days
A9F44210
Ampere: 10A, Brand: Schneider Electric, Ampere(C): 10A
Main Range Acti9 Product name Disbo iC60 product or component type Miniature circuit-breaker Device short name IC60N Poles description 2P Number of protected poles 2 [In] rated current 10 A Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 10 kA Icu at <= 125 V DC conforming to EN/IEC 60947-2 6000 A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1...
Ampere(C): 10A
In stock
7 days
A9F54106
Ampere: 6A, Brand: Schneider Electric, Ampere(C): 6A
Main Range Acti9 Product name Disbo iC60 product or component type Miniature circuit-breaker Device short name iC60H poles description 1P Number of protected poles 1 [In] rated current 6 A Network type AC/DC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 20 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 15 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 10000 A Icn at...
Ampere(C): 6A
In stock
7 days
A9N18362
Ampere: 100A, Brand: Schneider Electric, Ampere(C): 100A
Main Range of product C120 Range Acti9 Product name C120 product or component type Miniature circuit-breaker Device short name C120N Device application Distribution Poles description 2P Number of protected poles 2 Neutral position Left [In] rated current 100 A at 30 °C Network type AC Trip unit technology Thermal-magnetic Curve code C...
Ampere(C): 100A
In stock
7 days
A9N18363
Ampere: 125A, Brand: Schneider Electric, Ampere(C): 125A
Main Range of product C120 Range Acti9 Product name C120 product or component type Miniature circuit-breaker Device short name C120N Device application Distribution Poles description 2P Number of protected poles 2 Neutral position Left [In] rated current 125 A at 30 °C Network type AC Trip unit technology Thermal-magnetic Curve code C...
Ampere(C): 125A
In stock
7 days
A9N61501
Ampere: 1A, Brand: Schneider Electric, Ampere(C): 1A
  Range Acti9 Product name Acti9 C60H-DC product or component type Miniature circuit-breaker Device short name C60H-DC Device application Distribution poles description 1P Number of protected poles 1 [In] rated current 1 A at 25 °C Network type DC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 10 kA Icu at 220 V DC conforming to EN 60947-2 10 kA Icu at 220 V DC...
Ampere(C): 1A
In stock
7 days
17061
Ampere: 20A, Brand: Schneider Electric, Ampere(C): 20A
Main Range Domae product or component type Miniature circuit-breaker Device short name Domae MCB Device application Distribution Poles description 2P Number of protected poles 2 Neutral position Left [In] rated current 20 A Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity Icn 6000 A Complementary Network frequency...
Ampere(C): 20A
In stock
7 days
A9F44116
Ampere: 16A, Brand: Schneider Electric, Ampere(C): 16A
Main Range Acti9 Product name Disbo iC60 product or component type Miniature circuit-breaker Device short name IC60N Poles description 1P Number of protected poles 1 [In] rated current 16 A Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 10 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 6000 A Icn at...
Ampere(C): 16A
In stock
7 days
A9F44204
Ampere: 4A, Brand: Schneider Electric, Ampere(C): 4A
Main Range Acti9 Product name Disbo iC60 product or component type Miniature circuit-breaker Device short name IC60N Poles description 2P Number of protected poles 2 [In] rated current 4 A Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 50 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC...
Ampere(C): 4A
In stock
7 days
A9F44206
Ampere: 6A, Brand: Schneider Electric, Ampere(C): 6A
Main Range Acti9 Product name Disbo iC60 product or component type Miniature circuit-breaker Device short name IC60N Poles description 2P Number of protected poles 2 [In] rated current 6 A Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 10 kA Icu at <= 125 V DC conforming to EN/IEC 60947-2 6000 A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1 36 kA Icu...
Ampere(C): 6A
In stock
7 days
A9F44220
Ampere: 20A, Brand: Schneider Electric, Ampere(C): 20A
Main Range Acti9 Product name Disbo iC60 product or component type Miniature circuit-breaker Device short name IC60N Poles description 2P Number of protected poles 2 [In] rated current 20 A Network type AC/DC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 10 kA Icu at <= 125 V DC conforming to EN/IEC 60947-2 6000 A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1 36 kA...
Ampere(C): 20A
In stock
7 days
A9N61515
Ampere: 32A, Brand: Schneider Electric, Ampere(C): 32A
Main Range Acti9 Product name Acti9 C60H-DC product or component type Miniature circuit-breaker Device short name C60H-DC Device application Distribution poles description 1P Number of protected poles 1 [In] rated current 32 A at 25 °C Network type DC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 10 kA Icu at 220 V DC conforming to EN 60947-2 10 kA Icu...
Ampere(C): 32A
In stock
7 days
17049
Ampere: 32A, Brand: Schneider Electric, Ampere(C): 32A
Main Range Domae product or component type Miniature circuit-breaker Device short name Domae MCB Device application Distribution Poles description 1P Number of protected poles 1 [In] rated current 32 A Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity Icn 6000 A Complementary Network frequency 50/60 Hz [Ue] rated...
Ampere(C): 32A
In stock
7 days
17046
Ampere: 16A, Brand: Schneider Electric, Ampere(C): 16A
Main Range Domae product or component type Miniature circuit-breaker Device short name Domae MCB Device application Distribution Poles description 1P Number of protected poles 1 [In] rated current 16 A Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity Icn 6000 A Complementary Network frequency 50/60 Hz [Ue] rated...
Ampere(C): 16A
In stock
7 days
17059
Ampere: 10A, Brand: Schneider Electric, Ampere(C): 10A
Main Range Domae product or component type Miniature circuit-breaker Device short name Domae MCB Device application Distribution Poles description 2P Number of protected poles 2 Neutral position Left [In] rated current 10 A Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity Icn 6000 A Complementary Network frequency...
Ampere(C): 10A
In stock
7 days
A9F44163
Ampere: 63A, Brand: Schneider Electric, Ampere(C): 63A
Main Range Acti9 Product name Disbo iC60 product or component type Miniature circuit-breaker Device short name IC60N Poles description 1P Number of protected poles 1 [In] rated current 63 A Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 10 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 6000 A Icn at...
Ampere(C): 63A
In stock
7 days
A9F44110
Ampere: 10A, Brand: Schneider Electric, Ampere(C): 10A
Main Range Acti9 Product name Disbo iC60 product or component type Miniature circuit-breaker Device short name IC60N Poles description 1P Number of protected poles 1 [In] rated current 10 A Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 10 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 6000 A Icn at...
Ampere(C): 10A
In stock
7 days
EZ9F46232
Ampere: 32A, Brand: Schneider Electric, Ampere(C): 32A
Range Easy9 Device application Distribution product or component type Miniature circuit-breaker Device short name Easy9 MCB Poles 2P Number of protected poles 2 [In] rated current 32 A Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 3 kA Icu at 400 V AC 50/60 Hz conforming to SANS 60947-2 Utilisation category Category A Suitability for isolation Yes conforming to SANS 60947-2...
Ampere(C): 32A
In stock
7 days
A9F44202
Ampere: 2A, Brand: Schneider Electric, Ampere(C): 2A
Main Range Acti9 Product name Disbo iC60 product or component type Miniature circuit-breaker Device short name IC60N Poles description 2P Number of protected poles 2 [In] rated current 2 A Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 50 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC...
Ampere(C): 2A
In stock
7 days
A9F44232
Ampere: 32A, Brand: Schneider Electric, Ampere(C): 32A
Main Range Acti9 Product name Disbo iC60 product or component type Miniature circuit-breaker Device short name IC60N Poles description 2P Number of protected poles 2 [In] rated current 32 A Network type AC/DC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 10 kA Icu at <= 125 V DC conforming to EN/IEC 60947-2 6000 A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1 36 kA...
Ampere(C): 32A
In stock
7 days
A9F44232
Ampere: 40A, Brand: Schneider Electric, Ampere(C): 40A
Main Range Acti9 Product name Disbo iC60 product or component type Miniature circuit-breaker Device short name IC60N Poles description 2P Number of protected poles 2 [In] rated current 32 A Network type AC/DC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 10 kA Icu at <= 125 V DC conforming to EN/IEC 60947-2 6000 A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1 36 kA...
Ampere(C): 40A
In stock
7 days
A9F44250
Ampere: 50A, Brand: Schneider Electric, Ampere(C): 50A
Main Range Acti9 Product name Disbo iC60 product or component type Miniature circuit-breaker Device short name IC60N Poles description 2P Number of protected poles 2 [In] rated current 50 A Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 10 kA Icu at <= 125 V DC conforming to EN/IEC 60947-2 6000 A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1 36 kA...
Ampere(C): 50A
In stock
7 days
A9F44463
Ampere: 63A, Brand: Schneider Electric, Ampere(C): 63A
Main Range Acti9 Product name Disbo iC60 product or component type Miniature circuit-breaker Device short name IC60N Poles description 4P Number of protected poles 4 [In] rated current 63 A Network type AC/DC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 10 kA Icu at <= 250 V DC conforming to EN/IEC 60947-2 6000 A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1 36 kA...
Ampere(C): 63A
In stock
7 days
A9F54150
Ampere: 50A, Brand: Schneider Electric, Ampere(C): 50A
Main Range Acti9 Product name Disbo iC60 product or component type Miniature circuit-breaker Device short name iC60H poles description 1P Number of protected poles 1 [In] rated current 50 A Network type AC/DC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 20 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 15 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 10000 A Icn...
Ampere(C): 50A
In stock
7 days
A9N61533
Ampere: 25A, Brand: Schneider Electric, Ampere(C): 25A
Main Range Acti9 Product name Acti9 C60H-DC product or component type Miniature circuit-breaker Device short name C60H-DC Device application Distribution poles description 2P Number of protected poles 2 [In] rated current 25 A at 25 °C Network type DC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 10 kA Icu at 440 V DC conforming to EN 60947-2 10 kA Icu...
Ampere(C): 25A
In stock
7 days
17064
Ampere: 40A, Brand: Schneider Electric, Ampere(C): 40A
Main Range Domae product or component type Miniature circuit-breaker Device short name Domae MCB Device application Distribution Poles description 2P Number of protected poles 2 Neutral position Left [In] rated current 40 A Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity Icn 6000 A Complementary Network frequency...
Ampere(C): 40A
In stock
7 days
A9F44125
Ampere: 25A, Brand: Schneider Electric, Ampere(C): 25A
Main Range Acti9 Product name Disbo iC60 product or component type Miniature circuit-breaker Device short name IC60N Poles description 1P Number of protected poles 1 [In] rated current 25 A Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 10 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 6000 A Icn at...
Ampere(C): 25A
In stock
7 days
A9F44420
Ampere: 20A, Brand: Schneider Electric, Ampere(C): 20A
Main Range Acti9 Product name Disbo iC60 product or component type Miniature circuit-breaker Device short name IC60N poles description 4P Number of protected poles 4 [In] rated current 20 A Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 10 kA Icu at <= 250 V DC conforming to EN/IEC 60947-2 6000 A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1 36 kA...
Ampere(C): 20A
In stock
7 days
A9N18358
Ampere: 100A, Brand: Schneider Electric, Ampere(C): 100A
Main Range of product C120 Range Acti9 Product name C120 product or component type Miniature circuit-breaker Device short name C120N Device application Distribution Poles description 1P Number of protected poles 1 [In] rated current 100 A at 30 °C Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 3 kA Icu at 380...415 V...
Ampere(C): 100A
In stock
7 days
A9N18365
Ampere: 80A, Brand: Schneider Electric, Ampere(C): 80A
Main Range of product C120 Range Acti9 Product name C120 product or component type Miniature circuit-breaker Device short name C120N Device application Distribution Poles description 3P Number of protected poles 3 [In] rated current 80 A at 30 °C Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 10000 A Icn at 230...400...
Ampere(C): 80A
In stock
7 days
A9A26476
Main range of product Acti9 product or component type Shunt trip release Device short name iMX [Uc] control circuit voltage 100...415 V AC 50/60 Hz 110...130 V DC 9 mm pitches 2
In stock
7 days
A9A26960
range of product Acti9 product or component type Undervoltage release Device short name iMN [Uc] control circuit voltage 220...240 V AC 50/60 Hz Control type Standard 9 mm pitches 2
In stock
7 days
A9N61522
Ampere: 2A, Brand: Schneider Electric, Ampere(C): 2A
Main Range Acti9 Product name Acti9 C60H-DC product or component type Miniature circuit-breaker Device short name C60H-DC Device application Distribution Poles description 2P Number of protected poles 2 [In] rated current 2 A at 25 °C Network type DC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 10 kA Icu at 440 V DC conforming to EN 60947-2 10 kA Icu at...
Ampere(C): 2A
In stock
7 days
A9N61528
Ampere: 10A, Brand: Schneider Electric, Ampere(C): 10A
Main Range Acti9 Product name Acti9 C60H-DC product or component type Miniature circuit-breaker Device short name C60H-DC Device application Distribution Poles description 2P Number of protected poles 2 [In] rated current 10 A at 25 °C Network type DC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 10 kA Icu at 440 V DC conforming to EN 60947-2 10 kA Icu...
Ampere(C): 10A
In stock
7 days
17048
Ampere: 25A, Brand: Schneider Electric, Ampere(C): 25A
Main Range Domae product or component type Miniature circuit-breaker Device short name Domae MCB Device application Distribution Poles description 1P Number of protected poles 1 [In] rated current 25 A Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity Icn 6000 A Complementary Network frequency 50/60 Hz [Ue] rated...
Ampere(C): 25A
In stock
7 days
17060
Ampere: 16A, Brand: Schneider Electric, Ampere(C): 16A
Main Range Domae product or component type Miniature circuit-breaker Device short name Domae MCB Device application Distribution Poles description 2P Number of protected poles 2 Neutral position Left [In] rated current 16 A Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity Icn 6000 A Complementary Network frequency...
Ampere(C): 16A
In stock
7 days
17084
Ampere: 40A, Brand: Schneider Electric, Ampere(C): 32A
Main Range Domae product or component type Miniature circuit-breaker Device short name Domae MCB Device application Distribution Poles description 3P Number of protected poles 3 [In] rated current 40 A Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity Icn 6000 A Complementary Network frequency 50/60 Hz [Ue] rated...
Ampere(C): 32A
In stock
7 days
EZ9F46120
Ampere: 20A, Brand: Schneider Electric, Ampere(C): 20A
Range Easy9 Device application Distribution product or component type Miniature circuit-breaker Device short name Easy9 MCB Poles 1P Number of protected poles 1 [In] rated current 20 A Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 6000 A Icn at 230 V AC 50/60 Hz phase to neutral conforming to BS EN 60898-1 6000 A Icn at 400 V AC 50/60 Hz phase to phase conforming to BS EN 60898-1 Suitability for...
Ampere(C): 20A
In stock
7 days
A9F44263
Ampere: 63A, Brand: Schneider Electric, Ampere(C): 63A
Main Range Acti9 Product name Disbo iC60 product or component type Miniature circuit-breaker Device short name IC60N Poles description 2P Number of protected poles 2 [In] rated current 63 A Network type AC/DC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 10 kA Icu at <= 125 V DC conforming to EN/IEC 60947-2 6000 A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1 36 kA...
Ampere(C): 63A
In stock
7 days
A9F44440
Ampere: 40A, Brand: Schneider Electric, Ampere(C): 40A
Main Range Acti9 Product name Disbo iC60 product or component type Miniature circuit-breaker Device short name IC60N poles description 4P Number of protected poles 4 [In] rated current 40 A Network type AC/DC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 10 kA Icu at <= 250 V DC conforming to EN/IEC 60947-2 6000 A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1 36 kA...
Ampere(C): 40A
In stock
7 days
A9F44450
Ampere: 50A, Brand: Schneider Electric, Ampere(C): 50A
Main Range Acti9 Product name Disbo iC60 product or component type Miniature circuit-breaker Device short name IC60N poles description 4P Number of protected poles 4 [In] rated current 50 A Network type AC/DC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 10 kA Icu at <= 250 V DC conforming to EN/IEC 60947-2 6000 A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1 36 kA...
Ampere(C): 50A
In stock
7 days
A9F54110
Ampere: 10A, Brand: Schneider Electric, Ampere(C): 10A
Main Range Acti9 Product name Disbo iC60 product or component type Miniature circuit-breaker Device short name iC60H Poles description 1P Number of protected poles 1 [In] rated current 10 A Network type AC/DC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 20 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 15 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 10000 A Icn...
Ampere(C): 10A
In stock
7 days
17063
Ampere: 32A, Brand: Schneider Electric, Ampere(C): 32A
Main Range Domae product or component type Miniature circuit-breaker Device short name Domae MCB Device application Distribution Poles description 2P Number of protected poles 2 Neutral position Left [In] rated current 32 A Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity Icn 6000 A Complementary Network frequency...
Ampere(C): 32A
In stock
7 days
17062
Ampere: 25A, Brand: Schneider Electric, Ampere(C): 25A
Main Range Domae product or component type Miniature circuit-breaker Device short name Domae MCB Device application Distribution Poles description 2P Number of protected poles 2 Neutral position Left [In] rated current 25 A Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity Icn 6000 A Complementary Network frequency...
Ampere(C): 25A
In stock
7 days
EZ9F46140
Ampere: 40A, Brand: Schneider Electric, Ampere(C): 40A
Range Easy9 Device application Distribution product or component type Miniature circuit-breaker Device short name Easy9 MCB Poles 1P Number of protected poles 1 [In] rated current 40 A Network type AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 4500 A Icn at 230 V AC 50/60 Hz conforming to IEC 60898-1 4500 A Icn at 400 V AC 50/60 Hz conforming to IEC 60898-1 Suitability for isolation Yes conforming to IEC...
Ampere(C): 40A
In stock
7 days
A9F44432
Ampere: 32A, Brand: Schneider Electric, Ampere(C): 32A
Main Range Acti9 Product name Disbo iC60 product or component type Miniature circuit-breaker Device short name IC60N Poles description 4P Number of protected poles 4 [In] rated current 32 A Network type AC/DC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 10 kA Icu at <= 250 V DC conforming to EN/IEC 60947-2 6000 A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1 36 kA...
Ampere(C): 32A
In stock
7 days
A9F44416
Ampere: 16A, Brand: Schneider Electric, Ampere(C): 16A
Main Range Acti9 Product name Disbo iC60 product or component type Miniature circuit-breaker Device short name IC60N Poles description 4P Number of protected poles 4 [In] rated current 16 A Network type AC/DC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 10 kA Icu at <= 250 V DC conforming to EN/IEC 60947-2 6000 A Icn at 415 V AC 50/60 Hz conforming to EN/IEC...
Ampere(C): 16A
In stock
7 days
A9F54132
Ampere: 32A, Brand: Schneider Electric, Ampere(C): 32A
Main Range Acti9 Product name Disbo iC60 product or component type Miniature circuit-breaker Device short name iC60H Poles description 1P Number of protected poles 1 [In] rated current 32 A Network type AC/DC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 20 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 15 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 10000 A Icn...
Ampere(C): 32A