Online Payment with Payfast
Offline payment through IBFT (Inter Bank Fund Transfer)
Order more then Rs.25000/ order delivery free within City
Please read shipping policy
IBFT to Tradekul Pvt. Ltd. account
Payfast Payment gatways
In Schneider, we cover complete range of Low Voltage Switchgear including ACB’s, MCCB’s, MCB’s, MPCBs, Magnetic Contactors, Overload Relays, VFD’s, Soft Starters and Automation Devices etc.
Weidmuller provides Terminal Blocks, PCB Connectors, Marking Systems, Fieldbus Distribution Boxes, Solid State Relays, Power Supplies SPD’s, Enclosures and Cable Glands etc.
Hioki is a leading Electrical Measuring Instruments Manufacturer in the world providing AC/DC Clamp & Multimeters, Insulation & Earth Testers, Infrared Thermometers, Phase Detectors, Temperature & Humidity Loggers, Impedance Analyzers, Battery Testers, Power Meters, and Power Quality Analyzers etc.
Besides marketing genuine components we also provide customer support and after sales services. These two attributes are practiced by us in letter & spirit. This job is handled by a team of qualified engineers
Description
AC Current range | 60.00 A to 2000 A, 3 ranges (45 Hz to 1 kHz, True RMS), Basic accuracy 45-66 Hz: ±1.5% rdg. ±0.08 A (60 A range) |
---|---|
Crest factor | For the 60.00 A range: 2.5 (greater than 50.00 A and less than or equal to 60.00 A) to 2000 A range: 1.5 (2000 A or less) |
DC Voltage range | 600.0 mV to 1000 V (When using P2000: 600.0 V to 2000 V) |
AC Voltage range | 6.000 V to 1000 V, 4 ranges (15 Hz to 1 kHz, True RMS), Basic accuracy 45-66 Hz: ±0.9% rdg. 0.003 V (at 6 V) |
DC+AC Voltage range | 6.000 V to 1000 V, 4 ranges, Basic accuracy DC, 45-66 Hz: ±1.0% rdg. ±0.013 V (at 6 V) |
Resistance range | 600.0 Ω to 6.000 MΩ, 5 ranges, Basic accuracy: ±0.7% rdg. ±0.5 Ω (at 600 Ω) |
Electrostatic capacity range | 1.000 μF to 1000 μF, 4 ranges, Basic accuracy: ±1.9% rdg. ±0.005 μF (at 1 μF) |
Frequency range | Voltage: 9.999 Hz to 999.9 Hz 3 ranges, Current: 99.99 Hz to 999.9 Hz 2 ranges, Basic accuracy: ±0.1% rdg. ±0.01 Hz (at 99.99 Hz) |
Temperature (K) | -40.0 to 400.0 ˚C, Basic accuracy: ±0.5% rdg. ±3.0 ˚C + temperature probe accuracy |
Harmonic levels | [With Z3210 installed] Voltage/Current harmonic levels up to 30th, Content factor, Total harmonic distortion ratio *Harmonics can be displayed with our free app GENNECT Cross. |
Other functions | Continuity check, Diode check, Automatic AC/ DC detection (Voltage check only), Max/ Min/ AVG/ Peak waveform MAX/ Peak waveform MIN value display, Low-pass filter function, Display value hold, Backlight, Auto power save, Buzzer sound, Zero-adjustment, and other function |
Dustproof, waterproof | IP20 (current measurement of voltage or hazardous live conductors under completely dry condition. Do not use when wet.) IP50 (when measuring resistance, or current of an insulated conductor (completely dry), and in storage) |
Power supply | LR03 Alkaline battery ×2 Continuous use: approx. 48 hr (without Z3210 installed), approx. 24 hr. (with Z3210 installed and using wireless communications) Other conditions: 100 A AC measurement, backlight off, 23°C reference value |
Core jaw diameter | φ55 mm (2.17 in), Jaw dimension: 82 mm (3.23 in) W × 11 mm (0.43 in) D (D dimension is a range value of 44 mm (1.73 in) from the tip of the jaw) |
Smallest dimension of jaw cross-section | 11 mm (0.43 in) (Range value of 44 mm (1.73 in) from the tip of the jaw) |
Dimensions and mass | 65 mm (2.56 in) W × 247 mm (9.72 in) H × 35 mm (1.38 in) D, 300 g (10.6 oz) |
Included accessories | Test Lead L9300 ×1, Carrying Case C0203 ×1, LR03 Alkaline battery ×2, Instruction Manual ×2, Operating Precautions ×1 |
Give a Review