Description
Power supply |
Rechargeable lithium-ion battery packs 9.6V, backup charger. |
Battery indicator |
Battery symbol shows dump energy. When the voltage is too low, automatic shutdown after the 1 minute. |
Power consumption |
Current consumption of normal test 490 mA, continuous working for 10 hours. |
Display mode |
LCD color screen, 640dots×480dots, 5.6 inches, display domain: 116mm×88mm. |
Size of clamp |
FR008 small sharp current clamp: 8mm×15mm; FR020 circle current clamp: 20mm×20mm; FR050 circle current clamp: 50mm×50mm. FR300R Flexible Coil Current Sensor (with Integrator) : Ф300mm |
Instrument dimensions |
L×W×H: 277.2mm × 227.5mm × 153mm. |
Number of channels |
4U/4I. |
Phase-to phase voltage |
1.0V~2000V. |
Phase-to-neutral voltage |
1.0V~1000V. |
Current |
FR008 current clamp: 10mA~10.0A; FR020 current clamp: 0.10A~100A; FR050 current clamp: 1.0A~1000A; FR300R Flexible Coil Current Sensor (with Integrator) : 10A ~ 6000A |
Phase-to-neutral voltage |
1.0V~1000V. |
Parameters of electricity |
W, VA, Var, PF, DPF, cosφ, tanφ. |
Energy parameters |
Wh, Varh, Vah. |
Harmonic |
Order 0~50. |
Total harmonic distortion |
Order 0~50, each phase. |
Expert mode |
Yes. |
Number of Transient records |
150 sets. |
Voltage flicker |
Yes. |
Starting current mode |
Yes, 100 seconds. |
3 phases unbalance |
Yes. |
Record |
300 days(simultaneous recording 20 parameters, record one point every 5 seconds). |
Min/Max recorded value |
Measurement of maximum and minimum values over a period of time. |
Alarm |
40 different types of parameter selections, 12,800 sets alarm logs. |
Peak |
Yes. |
Phasor diagram display |
Automatically. |
Capacity of snapshots |
60. |
Menu language |
English/Chinese. |
Communication |
USB. |
Automatic switching off |
When an alarm campaign is initiated or a search for transients, an inrush current capture, or a trend recording is pending or in progress, the device is not automatic switching off. |
|
In other test mode, 15 minutes without keystrokes, automatic shutdown after prompt 1 minute. |
Backlight function |
Yes, suitable for use at night and dark place. |
Weight |
Host: 1.6kg (with battery). |
|
FR008 small sharp current clamp: 168g×4; |
|
FR020 circle current clamp: 252g×4; |
|
FR050 circle current clamp: 463g×4; |
|
FR300R Flexible Coil Current Sensor (with Integrator) : 280g×4; |
|
Test wires and power adapter: 800g; |
|
Total weight: about 10.8kg (with packaging). |
Length of voltage test wire |
3m. |
Length of current sensor wire |
2m. |
Working temperature and humidity |
-10°C~40°C; below 80%Rh. |
Storage temperature and humidity |
-10°C~60°C; below 70%Rh. |
Input impedance |
Input impedance of test voltage: 1MΩ. |
Withstand voltage |
Withstand 3700V/50Hz sinusoidal AC voltage for 1 minute between instrument wiring and shell. |
Insulation |
Between instrument wiring and shell ≥10MΩ. |
Structure |
Double insulation, with insulation vibration-proof sheath. |
Safely rules |
IEC 61010 1000V Cat III / 600V CAT IV, IEC61010-031, IEC61326, Pollution degree: 2. |