Description
Physical |
64 x 10 Gigabit Ethernet ports (48 10GBASE-T and 4 QSFP+)
48 RJ-45 ports support 100 Mbps and 1 and 10 Gigabit Ethernet
4 QSFP ports support 4 x 10 Gigabit Ethernet or 40 Gigabit Ethernet each |
Performance |
1.28-Tbps switching capacity
Forwarding rate of 950 mpps
Line-rate traffic throughput (both Layer 2 and 3) on all ports
Configurable Maximum Transmission Units (MTUs) of up to 9216 bytes (jumbo frames)
|
MAC addresses | 128,000 |
Number of VLANS | 4096 |
Spanning-tree instances |
Rapid Spanning Tree Protocol (RSTP): 512
Multiple Spanning Tree (MST) Protocol: 64
|
ACL entries |
2000 ingress
1000 egress
|
Routing table |
16,000 prefixes and 16,000 host entries
8000 multicast routes * |
Number of EtherChannels | 64 (with vPC) |
Number of ports per EtherChannel | 32 |
Buffers | 9 MB shared |
Boot flash memory | 2 GB |
Number of power supplies |
2 |
|
Power supply types |
AC (forward and reversed airflow)
DC (forward and reversed airflow)
|
|
Typical operating power | 362W (48p with 3m cables; 4 SR4 at 100% load) | |
Maximum power | ||
AC PSUs |
100 to 240 VAC
50 to 60 Hz
89 to 91% at 220V
|
|
Typical heat dissipation | 1235 BTU/hr (48p with 3m cables; 4 SR4 at 100% load) | |
Maximum heat dissipation | 1553 BTU/hr | |
Cooling |
Forward and reversed airflow schemes: Forward airflow: Port-side exhaust (air enters through fan-tray and power supplies and exits through ports)
Reversed airflow: Port-side intake (air enters through ports and exits through fan-tray and power supplies)
Single fan tray with redundant fans |
|
Sound |
Measured sound power (maximum) ● Fan speed: 40% duty cycle
● Fan speed: 60% duty cycle
● Fan speed: 100% duty cycle
● 59.7 dBA
● 66.4 dBA
● 71.0 dBA
|
|
Environment | 3064-32T: 1.72 x 17.3 x 22.45 in.(4.4 x 43.9 x 57.0 cm) |
Weight | 3064-32T: 20.8 lb (9.5 kg) |
Operating temperature | 32 to 104°F (0 to 40°C) |
Storage temperature | -40 to 158°F (-40 to 70°C) |
Operating relative humidity |
10 to 85% noncondensing
Up to 5 days at maximum (85%) humidity
Recommend ASHRAE data center environment
|
Storage relative humidity | 5 to 95% noncondensing |
Altitude | 0 to 10,000 ft (0 to 3000m) |
Give a Review